Carbon® Air Nitrile gloves come in a distinct black color, designed specifically to conceal stains during usage, maintaining a clean and professional appearance. Their enhanced fingertip texture offers superior handling and increases control, ensuring tasks are completed with precision and efficiency. In addition to chemotherapy drug tested, Carbon Air Nitrile Gloves are fentanyl and gastric acid resistant.
Key Features and Benefits
• Enhanced fingertip texture for superior handling and increased control. Distinct black color to minimize visible stains during use.
• Patented Low Derma Technology eliminates the chemical accelerators commonly found in nitrile, reducing the risk of Type I & Type IV hypersensitivities.
• Ultra 300 saver pack to reduce storage space and packaging waste.
•Tested and certified as the first nitrile gloves with resistance against Fentanyl
(510k granted by FDA).
Packaging Details
300 pieces per box by weight, 10 boxes per case
CR3365 (X-Small)
CR3366 (Small)
CR3367 (Medium)
CR3368 (Large)
CR3369 (X-Large) *250 gloves/box
PROTECTION AGAINST FENTANYL
Tested and certified as the first nitrile gloves with resistance against Fentanyl (510k granted by FDA).
CHEMOTHERAPY DRUG TESTED
Chemotherapy drug permeation tested for resistance to penetration by select drugs
PATENDED LOW DERMA TECHNOLOGY
Patented Low Derma Technology eliminates the chemical accelerators commonly found in nitrile, reducing the risk of Type I & Type IV hypersensitivities.
ASTM D6978 Chemotherapy Drugs Permeation Test *denotes mandatory chemotherapy drugs
Chemotherapy Drugs and Concentration | Concentration | Minimum Breakthrough Detection Time in Minutes |
---|---|---|
Carmustine* (BCNU) | 3.3 mg/ml | Do Not Use |
Cisplatin | 1.0 mg/ml | > 240 min |
Cyclophosphamide (Cytoxan)* | 20.0 mg/ml | > 240 min |
Cytarabine | 100 mg/ml | > 240 min |
Dacarbazine (DTIC) | 10.0 mg/ml | > 240 min |
Doxorubicin Hydrochloride* | 2.0 mg/ml | > 240 min |
Etoposide* | 20.0 mg/ml | > 240 min |
Fluorouracil* | 50.0 mg/ml | > 240 min |
Ifosfamide | 50.0 mg/ml | > 240 min |
Methotrexate | 25.0 mg/ml | > 240 min |
Mitomycin C | 0.5 mg/ml | > 240 min |
Mitoxantrone | 2.0 mg/ml | > 240 min |
Paclitaxel (Taxol)* | 6.0 mg/ml | > 240 min |
Thiotepa* | 10.0 mg/ml | Do Not Use |
Vincristine Sulfate | 1.0 mg/ml | > 240 min |
Chemotherapy Drugs and Concentration | Concentration | Minimum Breakthrough Detection Time in Minutes |
---|---|---|
Fentanyl Citrate Injection | 100mcg/2ml | > 240 min |
Awards
FAQ
-
Contact dermatitis is a skin condition that develops from repeated exposure to certain chemicals. In dental, this exposure is commonly found from remnants of chemical accelerators used in the manufacture of gloves.
-
D Chemical accelerators are used in glove manufacturing to stabilize synthetic rubber molecules into strong and durable gloves. These accelerators are the major cause of Allergic Contact Dermatitis reactions.
-
Accelerator-Free gloves are manufactured without the use of accelerator chemicals such as Mercaptobenzothiazole (MBTs), thiazoles, thiurams and dithiocarbamates to help protect glove users from a nonallergic reaction to any of the numerous irritants from both glove and non-glove associated sources.
-
For nitrile glove users, the possibility of glove allergy should be considered in all case of hand dermatitis. the usual culprits are additive chemicals called accelerators. because of their effects on the chemical reactions that change liquid rubber formulations into tough rubber films. Accelerator-free nitrile gloves are strongly recommended for people who are sensitive to these additives.
-
It varies, depends on the skin conditions (personal experience). The effectiveness can lead from 1 week to several months.